Solved exercises🧮 Solve my exercise

Baccalauréat 2023 — Physics-Chemistry specialty, Polynésie française — exercise 3 : Heat pump and dwelling (official exam paper)

PhysicsLevel : High schoolHeat pump and dwelling🌐 Lire en français
Statement
Concerned about reducing his carbon footprint, a private individual wishes to replace the gas boiler in his home with a low-carbon heating system. A specialized company then предлагает him an air/water heat pump. A heat pump, abbreviated as PAC, air/water is a heating device that transfers heat from the outside air to the hot water circulating in the home’s radiators. It consists of one unit located inside the home and another outside. The aim of this exercise is to study the compatibility of the heat pump with the individual’s home. Data: Characteristics of the heat pump studied: - Maximum power $P_{max}$ supplied to heat the radiator water: 7.0 kW. - Sound intensity level $L_1$ measured at 5 m from the outdoor unit: 46 dB. Thermodynamic study of the PAC. We consider a day when the outdoor temperature $T_{ext}$ is equal to 2 °C. A thermal transfer through the walls takes place from the indoor air of the house to the outdoor air. Figure 1. Cross-sectional diagram of the house’s brick wall with thermal resistance $R_{th}$: a vertical wall of thickness $e$ separates the interior on the left, at temperature $T_{int}=19\ ^\circ\mathrm{C}$, from the exterior on the right, at temperature $T_{ext}=2\ ^\circ\mathrm{C}$. Q1. Identify, with justification, the mode of heat transfer occurring through a wall. Recall that the heat flux $\phi$ is related to the temperature difference $T_{int}-T_{ext}$ and the thermal resistance $R_{th}$ by the relation: $\phi=\dfrac{T_{int}-T_{ext}}{R_{th}}$. In the case of the wall, the thermal resistance $R_{th}$ depends on the wall thickness $e$ (in m), its area $S$ (in m²), and a characteristic parameter of the material called thermal conductivity denoted $\lambda$ (in $\mathrm{W\cdot m^{-1}\cdot K^{-1}}$) by the relation: $R_{th}=\dfrac{e}{\lambda\times S}$. Q2. Using the two previous relations, indicate how the thermal flux $\phi$ changes when the wall thickness $e$ increases. Using a control system, the temperature of the home’s indoor air is kept constant at a value $T_{int}$ equal to 19 °C. The temperature of the hot water circulating in the radiators is $T_{rad}$ equal to 55 °C. Q3. Indicate and justify the direction of the heat transfer $Q_{rad/air}$ occurring between the radiators and the indoor air of the house. We wish to carry out a thermal balance of the "indoor air" system over a duration of one hour on this winter day. By convention, heat transfers are counted negatively when they are given off by the system and positively when they are received. We then consider a heat transfer between the indoor air and the walls, denoted $Q_{mur}$, as well as a heat transfer between the indoor air and the other surfaces (roof, windows, floor, etc.) denoted $Q_{autres}$. It is also assumed that the system does not exchange work with the outside. Data: - The duration of the thermal balance is one hour; - The heat transfer through the walls denoted $Q_{mur}$ is equal to − 4.3 MJ; - Heat transfer through the other surfaces denoted $Q_{autres}$ is equal to − 7.1 MJ; - $1\ \mathrm{MJ}=10^6\ \mathrm{J}$. Q4. Using the first law of thermodynamics for the "indoor air" system, show that: $Q_{rad/air}=-Q_{mur}-Q_{autres}$. Q5. Using the data, calculate the value of $Q_{rad/air}$. Q6. Deduce whether the power of the PAC is sufficient to heat the radiator water. Acoustic study of the PAC. The outdoor unit of the PAC generates noise, so the owner wishes to ensure that he will not expose his neighbors to noise pollution. The nearest neighboring property is located 5 m from where the PAC outdoor unit would be installed. The law requires limiting nighttime sound emergence to 3 dB. Sound emergence is defined as the difference between the ambient sound level including the PAC, and the usual sound level without taking the PAC into account. Data: - The sound intensity level $L$ is related to the sound intensity $I$ by the relation: $L=10\times\log\left(\dfrac{I}{I_0}\right)$, with $I_0=1{,}0\times10^{-12}\ \mathrm{W\cdot m^{-2}}$ reference sound intensity. $L$ is expressed in decibels (dB) and $I$ in watt per square meter ($\mathrm{W\cdot m^{-2}}$). - Under the conditions of the problem, when two sounds with intensities $I_1$ and $I_2$ overlap, the total intensity $I$ is the sum of $I_1$ and $I_2$. - The sound intensity level $L_1$ measured at 5 m from the outdoor unit is 46 dB. - The usual nighttime sound level $L_2$ (without taking the PAC into account) is 44 dB. Q7. Verify that the value of the sound intensity level $L$ is equal to 48 dB. Q8. Deduce whether the owner exposes his neighbors to nighttime noise pollution greater than the regulatory threshold.
⏳ Solution not generated yet

Open this statement in Expert Maths AI: the step-by-step solution is computed on demand, checked by a second resolution, then published here for everyone.

📝 See the solution

Have a similar exercise? Get it solved step by step, for free.

🧮 Solve my exercise