Baccalauréat 2026 — Physics-Chemistry specialty, Centres étrangers G1 (jour 2) — exercise 1 : The Arronax cyclotron (official exam paper)
Statement
Commissioned in 2008 in Nantes, the Arronax particle accelerator is a cyclotron.
It makes it possible to produce radioisotopes used in medical treatments and for research in nuclear medicine.
Photographic document: photograph of the Arronax particle accelerator in a technical room. Source: chu-nantes.fr/le-cyclotron-arronax.
The aim of this exercise is to study the general operation of a cyclotron in order to enable the production of radioisotopes, then to study their use in scintigraphy.
1. The operation of a cyclotron
A cyclotron is a particle accelerator, invented by M. Lawrence in 1931.
It is made up of two metallic cavities in the shape of half-cylinders separated by a distance denoted $d$. A gun makes it possible to produce the charged particles introduced into the device.
Between the two cavities, an alternating voltage $U$ is applied. It creates an electric field $\vec{E}$. The particles used are $\mathrm{H^-}$ ions obtained from hydrogen atoms. They are therefore subjected, between the two cavities, to an electric force $\vec{F_e}$ which accelerates them.
Inside the two cavities, a magnetic field forces the particles present to undergo uniform circular motion.
After a certain number of turns, the $\mathrm{H^-}$ ions pass through an extractor which removes their two electrons. At the exit, the formed protons $\mathrm{H^+}$ are directed towards a target, to produce the radioisotopes.
Figure 1 – Simplified diagram of a cyclotron: two large metallic semicircular cavities are separated by a central vertical region of width $d$. A horizontal axis $x$ passes through the center. On the left, a gun injects $\mathrm{H^-}$ ions near the center. The particle trajectory is shown with dashed lines: it forms a spiral that widens as it passes between the two cavities. The legend indicates that a black dot represents $\mathrm{H^-}$, a black diamond represents $\mathrm{H^+}$, and a dashed line represents the particle trajectory. At the bottom right, an extractor is placed on the trajectory; after this extractor, the particle is represented by a $\mathrm{H^+}$ diamond moving toward a rectangular target located on the right and labeled “Target”.
Figure 2 – Enlargement of the accelerating region when the $\mathrm{H^-}$ leaves the gun: two parallel vertical plates are separated by the distance $d$. The horizontal axis $x$ is oriented to the right; the origin $O$ is located at the level of the left plate. The $\mathrm{H^-}$ ion is represented between the plates, near $O$, with a horizontal dashed trajectory toward the right. An arrow “direction of motion” points to the right. The plates are indicated by a bracket.
The motion of the $\mathrm{H^-}$ ion between the plates is studied in a reference frame assumed to be Galilean, associated with the axis $(Ox)$. The $\mathrm{H^-}$ ion is emitted at point $O$ with no initial velocity.
Data:
- Mass of the $\mathrm{H^-}$ ion: $m = 1{,}67 \times 10^{-27}\ \mathrm{kg}$;
- Charge of the $\mathrm{H^-}$ ion: $q = -e = -1{,}6 \times 10^{-19}\ \mathrm{C}$;
- Distance between the plates: $d = 5{,}0\ \mathrm{mm}$;
- Voltage applied between the plates: $U = 65\ \mathrm{kV}$;
- Value of the electric field: $E = \dfrac{U}{d}$;
- $1\ \mathrm{eV} = 1{,}60 \times 10^{-19}\ \mathrm{J}$;
- Gravitational field strength $g = 9{,}81\ \mathrm{N\cdot kg^{-1}}$.
Q.1. Show that the magnitude of the weight of the $\mathrm{H^-}$ ion is negligible compared with the magnitude of the electric force $\vec{F_e}$ acting on the ion.
Q.2. Reproduce Figure 2 on your answer sheet. Complete this diagram by showing, without worrying about scale, the electric force $\vec{F_e}$ acting on the $\mathrm{H^-}$ ion and the electric field $\vec{E}$ present throughout the space between the plates.
Q.3. Express the acceleration $a_x$ of the $\mathrm{H^-}$ ion in the accelerating region as a function of $e$, $U$, $d$ and $m$, using Newton’s second law.
Q.4. Show then that the velocity and position of the $\mathrm{H^-}$ ion during its passage through the accelerating region, along the axis $x$, can be written as:
$V_x(t)=\dfrac{e.U}{m.d}\times t$
$x(t)=\dfrac{1}{2}\times \dfrac{e.U}{m.d}\times t^2$
Q.5. Calculate the value of the speed $v_{\mathrm{sortie}}$ of the $\mathrm{H^-}$ ion after the first passage through the accelerating region when $x(t)=d$.
Q.6. Verify that the kinetic energy of the $\mathrm{H^-}$ ion at the exit of the accelerating region is $E_c = 1{,}0 \times 10^{-14}\ \mathrm{J}$.
At each passage between the plates, the particles gain a kinetic energy equal to $1{,}0 \times 10^{-14}\ \mathrm{J}$. On the other hand, the particles do not gain kinetic energy in the cavities.
At the exit of the cyclotron, the particles have a kinetic energy of $70\ \mathrm{MeV}$.
Q.7. Calculate the number of complete turns the particles have made before leaving the cyclotron.
For this question, the candidate is invited to take initiative and present the method followed, even if it did not lead to a result. The method is assessed and must be presented clearly.
2. Radioisotope production and scintigraphy
Data:
- Information on some chemical elements: a two-column table “Oxygen” and “Fluorine”. Row “Symbol”: O for oxygen, F for fluorine. Row “Atomic number”: 8 for oxygen, 9 for fluorine.
- The energy of a photon is related to the wavelength of the emitted radiation by the relation:
$E=\dfrac{h\times c}{\lambda}$
with: $h$, Planck’s constant: $h = 6{,}63 \times 10^{-34}\ \mathrm{J\cdot s}$; $\lambda$, the wavelength of the radiation; $c$, the speed of electromagnetic waves in air and in vacuum, assumed known.
- $1\ \mathrm{eV} = 1{,}60 \times 10^{-19}\ \mathrm{J}$;
- Electromagnetic wave regions: diagram of a wavelength spectrum $\lambda$ marked approximately from $1\ \mathrm{pm}$ to $1\ \mathrm{km}$. From left to right: $\gamma$ rays at very small wavelengths, then X-rays, U.V. around $1\ \mathrm{nm}$ to $1\ \mathrm{\mu m}$, a very narrow visible band around a few hundred nm, I.R. from about $1\ \mathrm{\mu m}$ to $1\ \mathrm{mm}$, microwaves around $1\ \mathrm{mm}$ to $1\ \mathrm{m}$, radio waves beyond $1\ \mathrm{m}$ up to $1\ \mathrm{km}$. Source: Wikiversity.
The protons accelerated by the cyclotron make it possible to produce radioisotopes such as fluorine 18. Radioactive fluorine 18 is part of fluorodeoxyglucose (FDG), a radioactive tracer that accumulates in cancerous areas. The decay of this tracer emits photons. These are detected and analyzed using a gamma camera, placed around the area to be studied.
Scintigraphy is performed in a hospital nuclear medicine department, during an examination carried out in several stages:
- injection into a vein of a small quantity of the radioactive tracer;
- waiting about 1 h for the tracer to spread and attach itself in the body;
- recording and producing images of the organ to be studied, then analyzing these images. This step lasts about 30 minutes;
- the patient leaves the hospital 2 h after the start of the examination.
Photographic document: photograph of a lying patient entering the ring of a medical imaging device. Source: arronax-nantes.fr/production-des-radionucleides.
To form fluorine 18, the $\mathrm{H^+}$ protons (whose symbolic representation is $^{1}_{1}\mathrm{H}$) accelerated by the cyclotron bombard a target rich in oxygen 18. During this reaction, a neutron (denoted $^{1}_{0}n$) is also produced.
Q.8. Write the nuclear reaction equation leading to the formation of fluorine 18.
The fluorine 18 contained in the radioactive tracer decays by $\beta^+$ radioactivity.
Q.9. Give the name and symbol of the particle emitted during a $\beta^+$ radioactive decay. Write the nuclear transformation equation corresponding to this decay.
This decay is accompanied by the emission of photons whose average energy is $511\ \mathrm{keV}$.
Q.10. Calculate the wavelength corresponding to the average energy carried by the photon. Then justify the use of a gamma camera to analyze this radiation.
For the rest, let $N_0$ be the number of fluorine 18 nuclei contained in the tracer at time $t = 0\ \mathrm{s}$, corresponding to the time of injection, and let $N(t)$ be the number of fluorine 18 nuclei present in the patient’s body at time $t$.
The differential equation giving the number of nuclei $N(t)$ as a function of time is of the form:
$\dfrac{\mathrm{d}N(t)}{\mathrm{d}t} = -\lambda \times N(t)$ with $\lambda$ the radioactive constant.
Q.11. Show that the expression $N(t)=N_0\times e^{-\lambda \times t}$ is indeed a solution of the previous differential equation.
The graph below models the percentage of remaining nuclei $(N(t)/N_0)$ over time: graph with horizontal axis “Time (s)” marked from 0 to about 32 000 s, and vertical axis “Percentage of remaining nuclei (%)” marked from 0 to 100 %. The green curve $N(t)/N_0$ in % decreases exponentially: it is 100 % at $t=0$, about 60 % around 5 000 s, 40 % around 8 500 s, 30 % around 11 000 s, 20 % around 15 000 s, 10 % around 21 500 s and about 3 to 4 % around 32 000 s. The 50 % level is read around $6{,}5\times 10^3$ to $6{,}7\times 10^3\ \mathrm{s}$.
The relationship between the radioactive constant $\lambda$ and the half-life $t_{1/2}$ is: $t_{1/2}=\dfrac{\ln(2)}{\lambda}$.
Q.12. Define and then determine graphically the value of the half-life $t_{1/2}$ of fluorine 18.
Q.13. Calculate the value of the radioactive constant $\lambda$ corresponding to fluorine 18.
Q.14. Determine the percentage of radioactive tracer remaining in the patient’s body after the image analysis.
Q.15. Calculate the time needed for there to be less than 1 % of radioactive tracer remaining in the patient’s body. Comment on this value.
⏳ Solution not generated yet
Open this statement in Expert Maths AI: the step-by-step solution is computed on demand, checked by a second resolution, then published here for everyone.
📝 See the solutionHave a similar exercise? Get it solved step by step, for free.
🧮 Solve my exercise